Running a SYSTASK command results in an āAccess is deniedā message as well as a āCould not create a new processā error.
This problem occurs when all of the following conditions are true:
The problem does not occur when the SAS Object Spawner is running under the LocalSystem account
The workaround is to edit the WorkspaceServer_usermods.bat file in SAS\SAS-configuration-directory\Lev1\SASApp\WorkspaceServer\. In the file, add -limitui to the USERMODS_OPTIONS line. Save the BAT file, and then invoke the SASĀ® Workspace Server.
Click the Hot Fix tab in this note to access the hot fix for this issue.
Product Family | Product | System | Product Release | SAS Release | ||
Reported | Fixed* | Reported | Fixed* | |||
SAS System | Base SAS | Microsoft Windows Server 2012 Datacenter | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |
Microsoft Windows Server 2012 R2 Datacenter | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 | ||
Microsoft Windows Server 2012 R2 Std | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 | ||
Microsoft Windows Server 2012 Std | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 | ||
Microsoft Windows Server 2016 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 | ||
Microsoft Windows Server 2019 | 9.4_M6 | 9.4_M7 | 9.4 TS1M6 | 9.4 TS1M7 |